Wind turbines - Part 12-2: Power performance of electricity-producing wind turbines based on nacelle anemometry |
|
1 |
|
The Japan Electrical Manufacturers' Association |
b |
| |
Wind energy generation systems - Part 3-2: Design requirements for floating offshore wind turbines |
|
1 |
|
The Japan Electrical Manufacturers' Association |
b |
| |
Wind energy generation systems-Part 6: Tower and foundation design requirements |
|
1 |
|
The Japan Electrical Manufacturers' Association |
b |
| |
Design requirements for offshore wind turbines |
|
1 |
|
The Japan Electrical Manufacturers' Association |
b |
| |
Wind turbines-Part 12-1:Power performance measurements of electricity producing wind turbines |
|
1 |
|
The Japan Electrical Manufacturers' Association |
b |
| |
Method of test and calculation of the energy efficiency for electric toilet seats |
|
1 |
|
Japan Sanitary Equipment Industry Association |
b |
| |
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery-Safety- Part 2-23:Particular requirements for hand-held die grinders and small rotary tools
|
|
1 |
|
The Japan Electrical Manufacturers' Association |
b |
| |
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery-Safety- Part 3-13:
Particular requirements for transportable drills
|
|
1 |
|
The Japan Electrical Manufacturers' Association |
b |
| |
Combiner boxes for photovoltaic generating system |
|
1 |
|
The Japan Electrical Manufacturers' Association |
b |
| |
Protection of persons and equipment by enclosures for electrical apparatus-Probes for verification |
|
1 |
|
Japanese Standards Association |
b |
| |
Organic light emitting diode (OLED) light sources for general lightingSafety-Part 2-4: Particular requirements for safety– Rigid OLED tiles and panels |
|
1 |
|
※Japanese Standards Association |
b |
| |
Reed switches – Part 4: Application in conjunction with Magnetic Actuator used for Magnetic Sensing Devices
|
|
1 |
|
※Japanese Standards Association |
b |
| |
Fire hazard testing - Part 1-21: Guidance for assessing the fire hazard of electrotechnical products - Ignitability - Summary and relevance of test methods |
|
1 |
|
※Japanese Standards Association |
b |
| |
Fire hazard testing - Part 6-2: Smoke obscuration - Summary and relevance of test methods |
|
1 |
|
※Japanese Standards Association |
b |
| |
Superconductivity - Part 26: Critical current measurement - DC critical current of RE-Ba-Cu-O composite superconductors
|
|
2 |
|
※Japanese Standards Association |
b |
| |
Environmental testing – Part 2-87: Tests – UV-C exposure of materials and components to simulate ultraviolet germicidal Irradiation or other applications |
|
2 |
|
※Japanese Standards Association |
b |
| |
Environmental testing - Part 2-86: Tests -Test Fx: Vibration - Multi-exciter and multi-axis method |
|
2 |
|
※Japanese Standards Association |
b |
| C0364-7-710 |
Low-voltage electrical installations-Part 7-710: Requirements for special installations or locations-Medical locations |
91.140.50;29.020 |
5 |
IEC 60364-7-710 |
Japanese Standards Association |
b |
| C1291 |
Performance and testing method of active energy measurement for power electronic converter systems and equipment |
17.220.20 |
5 |
|
The Japan Electrical Manufacturers' Association |
b |
| C4034-30-1 |
Rotating electrical machines-Part 30-1: Efficiency classes of single-speed, three-phase, cage-induction motors (IE-code) |
29.160 |
4 |
IEC 60034-30-1 |
The Japan Electrical Manufacturers' Association |
b |
| C4442 |
Electrical energy storage (EES) systems-Safety requirements for grid-integrated EES systems-Performing unplanned modification of electrochemical based system |
13.020.30 |
5 |
IEC 62933-5-3 |
The Institute of Electrical Engineers of Japan |
b |
| C60529 |
Degrees of protection provided by enclosures (IP Code) |
13.260;29.020 |
5 |
IEC 60529,IEC 60529 Amendment 1,IEC 60529 Amendment 2 |
Japanese Standards Association |
b |
| C60695-1-12 |
Fire hazard testing-Part 1-12: Guidance for assessing the fire hazard of electrotechnical products-Fire safety engineering |
13.220.40; 29.020 |
5 |
IEC 60695-1-12 |
※Japanese Standards Association |
b |
| C60695-1-20 |
Fire hazard testing-Part 1-20: Guidance for assessing the fire hazard of electrotechnical products-Ignitability-General guidance |
13.220.40; 29.020 |
5 |
IEC 60695-1-20 |
※Japanese Standards Association |
b |
| C61400-1 |
Wind energy generation systems-Part 1: Design requirements |
27.180 |
5 |
IEC 61400-1 |
The Japan Electrical Manufacturers' Association |
b |
| C62282-9-101 |
Fuel cell technologies-Part 9-101: Evaluation methodology for the environmental performance of fuel cell power systems based on life cycle thinking-Streamlined life-cycle considered environmental performance characterization of stationary fuel cell combined heat and power systems for residential applications |
27.070 |
5 |
IEC TS62282-9-101 |
The Japan Electrical Manufacturers' Association |
b |
| C62733 |
Programmable components in electronic controlgear for electric light sources-General and safety requirements |
29.140.99 |
4 |
IEC 62733 |
※Japanese Standards Association |
b |
| C62841-3-9 |
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery-Safety-Part 3-9: Particular requirements for transportable mitre saws |
25.140.20 |
4 |
IEC 62841-3-9 |
The Japan Electrical Manufacturers' Association |
b |
| C63027 |
Photovoltaic power systems-DC arc detection and interruption |
27.160;29.020 |
5 |
IEC 63027 |
The Japan Electrical Manufacturers' Association |
b |
| C63294 |
Test methods for electric cables with rated voltages up to and including 450/750 V |
29.060.20 |
5 |
IEC 63294 |
※Japanese Standards Association |
b |
| H7350 |
Superconductivity-Superconducting electronic devices-Generic specification for sensors and detectors |
29.050;17.220 |
5 |
IEC 61788-22-1 |
The Japanese Electric Wire & Cable Makers' Association |
b |